Time frequency synchronous analyzer

Time frequency synchronous analyzer

LX-980 Time analyzer / Synchronization Time tester

The LX-980 time -frequency synchronization analyzer adopts the flat-panel operation mode, and is com...

Description


The LX-980 time -frequency synchronization analyzer adopts the flat-panel operation mode, and is compatible with GPS/BD signal access, as well as high -quality tame rubidium atomic clock. It has the characteristics of powerful function, high accuracy, and long endurance. It can accurately measure the pulse signal, IRIG - B AC and DC, serial port time message, SNTP network time message, and IEEE1588        precise network time synchronization message and other time synchronization signals, and can automatically identify the type of measured signal, It supports the measurement of the accuracy, standard deviation, amplitude, pulse width, etc. of the time signal, and can reproduce high -precision UTC time and generate high -precision clock as the test benchmark. It is applicable to power supply bureaus, power transmission and transformation companies, maintenance companies, electric power research institutes, enterprises and institutions that need time calibration, time measurement and time testing.

It supports the storage of PTP timestamp original data (T1, T2, T3, T4) and correction domain, and can quickly perform fault location and abnormal cause analysis.


Main features

Dual power supply redundancy hardware design

Message processing based on hardware timestamp

User configurable PTP/NTP

Telecom in accordance with ITU-T G.8265 . 1 standard

Support 2-channel satellite time source input

Automatic switching to select preferred reference source

WEB/SNMP management


Product technical indicators

GNSS Input Options

Test signal type

 

 

 

 

Measurement content

 

Parse content

   GPS GLONASS GALILEO BeiDou

  1PPS/PPM/PPH    (TTL /  RS485 /  RS422 /  RS232 /)

○  IRIG-B  (DC)  (TTL  /  RS485 /  RS422 /  RS232)

 Serial  port  Time  message  (RS485 /  RS422 /  RS232  )

  PTP /  NTP /  SNTP  Network  Time  message

Level high and low amplitude, rising edge time, pulse signal width, time accuracy of second timing, standard deviation

of time accuracy, SOE, etc., support single or continuous measurement.

IRIG-B, serial port time message, PTP/NTP/SNTP network time message

 Completion of time deviation/drift test and PDV test

 Store PTP timestamp original data (T1, T2, T3, T4) and correction domain for fault location and abnormal cause analysis

 PTP, NTP, 1PPS+TOD and other message information are captured and analyzed for a long time (supporting 500G data storage)

Self-maintenance 

stability of the device        ○  It  is  better  than  50ns/h,  and  supports  continuous  and  long  time  self-keeping  accuracy  measurement  record

Resolution                                ○  Time  and  clock  test  resolution  100ps

Frequency stability    

 of automorphic time         ○ 3 × E- 11/month, rubidium clock: better than (including) 1 μS/day; OCXO: better than (including) 1 μs/hTaming time:≥ 12h

Accuracy of 

measurement content          ○  1PS/PPM/PPH  pulse  signal  is  better  than  50ns

○  IRIG-B  (DC)  is  better  than  50ns

○  IRIG-B  (AC)  is  better  than  50ns

  Serial  port  message  is  better  than  50ns

○  PTP  network  time  message  is  better  than  50ns

 


PREV:Nothing~ NEXT:Nothing

Welcome your product consultation

Our staff will contact you as soon as they receive feedback.